Ni Usb 6008 Driver



USB-6008

Data Acquisition Toolbox™ Support Package for National Instruments ® NI-DAQmx Devices provides support for CompactDAQ, X-Series, M-Series, E-Series, USB, myDAQ, ELVIS II, and many other types of data acquisition hardware from National Instruments through MATLAB ® and Data Acquisition Toolbox.

The NI USB-6008 (Part Number: 779051-01) is a Bus-Powered Multifunction I/O Device. There are eight single-ended or four differential USB 6008 analog input channels, two USB 6008 analog output channels, and 12 digital input/output channels. The analog output channels can generate software timed outputs from 0 Volts to 5 Volts. Popular Driver Downloads NI-DAQmx. Provides support for NI data acquisition and signal conditioning devices. Provides support for Ethernet, GPIB, serial, USB. NI サンプルファインダに含まれている Cont Gen Voltage Wfm-Int Clk.vi や Gen Mult Volt Updates-Int Clk.vi 等を実行すると、下記の様なエラーが発生します。PCI-6251 や他の USB デバイスでは起こりません。何故 USB-6008/6009 では上記のメッセージが表示されるのでしょうか。.

8 analog inputs at 12 or 14 bits,up to 48 kS/s
NI [National Instruments Corporation]
1.USB-6008.pdf (5 pages)
  • Current page: 1 of 5
12- or 14-Bit, up to 48 kS/s, 8 Analog Inputs
• 8 analog inputs at 12 or 14 bits,
• 12 TTL/CMOS digital I/O lines
• Digital triggering
• 1-year warranty
• Windows Vista (32- and 64-bit)/XP/2000
• Linux
• Windows CE
With recent bandwidth improvements and new innovations from
National Instruments, USB has evolved into a core bus of choice for
measurement applications. The NI USB-6008 and USB-6009 are low-
cost entry points to NI flagship data acquisition (DAQ) devices. With
plug-and-play USB connectivity, these modules are simple enough for
quick measurements but versatile enough for more complex
where low cost, small form factor, and simplicity are essential.
• Data logging – quick and easy environmental or voltage data logging
• Academic lab use – student ownership of DAQ hardware for
Recommended Software
National Instruments measurement services software, built around
NI-DAQmx driver software, includes intuitive application programming
interfaces, configuration tools, I/O assistants, and other tools
designed to reduce system setup, configuration, and development time.
National Instruments recommends using the latest version of NI-DAQmx
USB-6009
SE = single ended, DI = differential
up to 48 kS/s
The USB-6008 and USB-6009 are ideal for a number of applications
completely interactive lab-based courses (Academic pricing available.
®
1
Bus
USB
1
8 SE/4 DI
Inputs
2
for details.)
Input
14
Recommended Software
• LabVIEW SignalExpress
• Measurement Studio
• C#, Visual Basic .NET
Measurement Services
• NI-DAQmx driver software
• LabVIEW SignalExpress LE
Base for these operating systems.
Sampling Rate
(kS/s)
48
±1 to ±20
Range
(V)
Analog
2
driver software for application development in NI LabVIEW, LabVIEW
SignalExpress, LabWindows/CVI, and Measurement Studio software.
ni.com/support/daq/versions.
• A guide to create fast and accurate measurements with no
Ni Usb 6008 Driver
• Automatic code generation to create your application in LabVIEW.
• LabWindows/CVI; LabVIEW SignalExpress; and C#, Visual Studio .NET,
• Multithreaded streaming technology for 1,000 times
• Automatic timing, triggering, and synchronization routing
• More than 3,000 free. software downloads available at
• Software configuration of all digital I/O features without
• Single programming interface for analog input, analog output,
NI measurement services software speeds up your development with
ANSI C/C++, or Visual Basic using Measurement Studio.
to make advanced applications easy.
hardware switches/jumpers.
digital I/O, and counters on hundreds of multifunction DAQ hardware
devices. M Series devices are compatible with the following versions
Ni usb 6008 install driver
(or later) of NI application software – LabVIEW, LabWindows/CVI, or
Measurement Studio versions 7.x; and LabVIEW SignalExpress 2.x.
Output
12
to jump-start your project.
Rate
150
Output
0 to 5
(V)
Lines
12
Counter
1
Trigger
Digital

USB-6008 Summary of contents

Page 1

... USB connectivity, these modules are simple enough for quick measurements but versatile enough for more complex measurement applications. The USB-6008 and USB-6009 are ideal for a number of applications where low cost, small form factor, and simplicity are essential. Examples include: • Data logging – quick and easy environmental or voltage data logging • ...

Page 2

... Base driver software is provided for use with Linux, Mac OS X, Windows Mobile, and Windows CE operating systems. Recommended Accessories The USB-6008 and USB-6009 have removable screw terminals for easy signal connectivity. For extra flexibility when handling multiple wiring configurations, NI offers the USB-600x Connectivity Kit, which includes two extra sets of screw terminals, extra labels, and a screwdriver ...

Page 3

... Number of channels............................ 12 total 1 Maximum ( ˚C) (mV) 138 Direction control ................................. Each channel individually 84.8 58.4 Output driver type 53.1 45.1 USB-6008........................................ Open-drain 42.5 USB-6009........................................ Each channel individually 38.9 37.5 Compatibility ....................................... CMOS, TTL, LVTTL Internal pull-up resistor ...................... 4.7 kΩ Power-on state.................................... Input (high impedance) Absolute maximum voltage range...... -0.5 to +5.8 V Single-Ended ...

National Instruments Usb 6008

Page 4

... USB (4.10 to 5.25 VDC)....................... 80 mA typical 500 mA maximum USB suspend....................................... 300 µA typical 500 µA maximum Environmental The USB-6008 and USB-6009 are intended for indoor use only. Operating environment Ambient temperature range ........... °C (tested in accordance with IEC-60068-2-1 and IEC-60068-2-2) Relative humidity range ................. 10 to 90%, noncondensing ...

Page 5

NI Services and Support NI has the services and support to meet your needs around the globe and through the application life cycle – from planning SERVICE and development through deployment NEEDS and ongoing maintenance. We offer services and service ...

Related keywords

  • USB-6008 datasheet
  • USB-6008 data sheet
  • USB-6008 pdf datasheet
  • USB-6008 component
  • USB-6008 part
  • USB-6008 distributor
  • USB-6008 RoHS
  • USB-6008 datasheet download

NI USB 6008 DRIVER DETAILS:

Type:Driver
File Name:ni_usb_38420.zip
File Size:651.3 KB
Rating:
46 (3.8)
Downloads:30
Supported systems:Windows All
Price:Free* (*Free Registration Required)



Have you tried using the DAQ assistant to set up an analog output? Can you share your code?

Differential coupling is of course more robust against differences in grounding potentials, so it should be the default coupling ni usb 6008. Figure 7: The Create New Task dialog window You must define one task for each of the input or output operations, i. Click a thumbnail to view larger image:. Feedback on optoscience from others who bought this item. Back to home page. Listed in category:.

Email to friends Share on Facebook - opens in a new window or tab Share on Ni usb 6008 - opens in a new window or tab Share on Pinterest - opens in a new window or tab Add to watchlist. Image not available Photos not available for this variation.

To ni usb 6008 a new task, press the Create New Task button, causing the dialog window shown in the figure below to be opened. You must define one task for each of the input or output operations, i. United States. Turn on suggestions. Ha My Dong view profile. Vote 0.

Ground-Referenced Signal Sources A ground-referenced signal source is a signal source connected to the building system ground. It is already connected to a common ground point with respect to the device, assuming that the computer is plugged into the same power system as ni usb 6008 source. Non-isolated outputs of instruments and devices that plug into the building power system fall into this category. The difference in ground potential between two instruments connected to the same building power system is typically between 1 and mV, ni usb 6008 the difference can be much higher if power distribution circuits are improperly connected.

National Instruments NI USB User Manual - Page 1 of 32

If a grounded signal source is incorrectly measured, this difference can appear as measurement error. Follow the connection instructions for grounded signal sources to eliminate this ground potential difference from the measured signal. Use differential connections instead. As shown in the bottom-rightmost cell of Table 6, there ni usb 6008 be a potential difference between GND and the ground of the sensor. In RSE mode, this ground loop causes measurement errors. The differential input mode can measure 20 V signals in the 20 V range. However, the maximum voltage on any one pin is 10 V with respect to GND. When no signals are connected to the analog input terminal, the internal resistor divider may cause the terminal to float to approximately 1.

You can zoom in close to see the ni usb 6008 with the serial number or zoom out to see the overall condition of the equipment.

A quick guide to National Instruments USB-6008

VI ni usb 6008 connected it directly into a waveform ni usb 6008 indicator so that the user can see the waveform of the file on the front panel. I created 2 case structures: one to analyze what note was being played, and the other to determine if the string needed to be turned up or down.

Your bid is the same as ni usb 6008 more than the Buy It Now price. You can save time and money by buying it now. Current bid:. Increase your maximum bid:. Feedback on optoscience from others who bought this item. PS: I know matlab can do this but it's way to expensive for me. By Ni usb 6008 Kowalsky. Above we created a task for an analog input.

Ni Usb-6008 Labview Driver

A quick guide to National Instruments USB-6008

You can create a task for analog output in the same way, that is, by selecting Create Task in the right-click menu of the USB device as it appears under Devices and Interfacessee Figure 8. The configuration can be saved using ni usb 6008 Save button, see Figure The most recent settings are saved, and are loaded the next time Ni usb 6008 is opened.

Ni Usb 6008 Driver Installer

There may be a small difference between the values due to the limited resolution in the DA-converter digital-to-analog and in the AD-converter analog-to-digital.8 AI (Bit, 10 kS/s), 2 AO ( Hz), 12 DIO USB Multifunction I/O Device—The USB‑ is a low-cost, multifunction DAQ device. It offers analog I/O, digital I/O. This user guide describes how to use the National Ni usb 6008 USB and National Instruments USB data acquisition (DAQ) devices. The NI.

Related Posts